ATR 42-320 PK-YRP (Trigana Air Service) — Sepinggan Airport, Balikpapan
- Nomor investigasi
- KNKT.10.02.04.04
- Waktu kejadian
- Lokasi
- Sepinggan Airport, Balikpapan
- Wilayah administratif
- KOTA BALIKPAPAN, KALIMANTAN TIMUR
Kronologi & deskripsi kejadian
The aircraft was departured from Kalimarau airport, Berau, East Kalimantan to Termindung Airport, Samarinda, East Kalimantan. ATS Balikpapan informed to ATS Berau that the aircraft divert to Balikpapan due to one engine failed.
Data teknis
| Operator / maskapai | — |
|---|---|
| Registrasi | — |
| Tipe pesawat | — |
| Nomor penerbangan | — |
| MTOW | — |
| Tahun pembuatan | — |
| Tipe operasi | — |
| Fase penerbangan | Landing (LDG) |
| Tipe pendekatan | — |
| Jenis kejadian | System/Component Failure or Malfunction (Powerplant) |
| Jenis kejadian II | Engine Flame-out |
| Teritori | — |
| Dimensi runway | — |
| Kode / nomor runway | — |
| Kondisi runway | — |
| Separasi horizontal | — |
| Separasi vertikal | — |
| Koordinat | — |
| Sumber laporan | — |
Korban
Faktor penyebab & kontributor
- Technical
Sarana & operator terkait
| Operator | Flight Number | Registrasi | Tipe Pesawat | Mtow | Tahun Pembuatan | Tipe Operasi | File Final Report |
|---|---|---|---|---|---|---|---|
| Trigana Air Service | — | PK-YRP | ATR 42-320 | above 5,700 kg | 1987 | AOC 121 | — |
Rekomendasi keselamatan yang diterbitkan
Penerima: Directorate General of Civil Aviation
-
— OPEN 0 tanggapan
Ensure that FDR and CVR read out are correct from the actual last flight data, during C of A renewal.
Lihat butir & lini masa tanggapan -
— OPEN 0 tanggapan
Ensure the quality system of the operator was function as required by the regulation, in order to avoid such wing tank sealant uncured and dirt.
Lihat butir & lini masa tanggapan
Penerima: Trigana Air Services
-
— OPEN 0 tanggapan
Ensure that the wing tank is clean and free from debris.
Lihat butir & lini masa tanggapan -
— OPEN 0 tanggapan
Ensure the actual of fuel quantity on both fuel tanks was equal and balance prior departure.
Lihat butir & lini masa tanggapan -
— OPEN 0 tanggapan
Ensure the FDR and CVR read out and calibration in accordance to the manufacture standard and should be done by approved repair station.
Lihat butir & lini masa tanggapan -
— OPEN 0 tanggapan
Ensure that the modification of fuel system referred to service bulletin No ATR42-28-039 and technical instruction No: 006/ENG-07/2008, was tested referred to the correct procedure as per AMM (JIC) 28-42-00 FUT 10000.
Lihat butir & lini masa tanggapan -
— OPEN 0 tanggapan
Review and improve the Implementation of CRM and technical knowledge.
Lihat butir & lini masa tanggapan -
— OPEN 0 tanggapan
Ensure that the correct sealant type for the wing tank application and correct procedure to be followed to avoid uncured process of it.
Lihat butir & lini masa tanggapan